Model No.: CDI-E180G0R75T4B
Frequency Inverter type | Rated capacity | Rated input current | Rated output current | Matchable Motor |
(KVA) | (A) | (A) | (kW) | |
CDI-E180G0R75T4B | 1.5 | 3.4 | 2.3 | 0.75 |
CDI-E180G1R5T4B | 3 | 5 | 3.7 | 1.5 |
CDI-E180G2R2T4B | 4 | 5.8 | 5 | 2.2 |
CDI-E180G3R7/P5R5T4B | 5.9/8.5 | 10.5/15.5 | 8.8/13 | 3.7/5.5 |
CDI-E180G5R5MT4B | 8.5 | 15.5 | 13 | 5.5 |
CDI-E180G5R5/P7R5T4B | 8.5/11 | 15.5/20.5 | 13/17 | 5.5/7.5 |
CDI-E180G7R5/P011T4B | 11./17 | 20.5/26 | 17/25 | 7.5/11 |
CDI-E180G011MT4B | 17 | 26 | 25 | 11 |
CDI-E180G011/P015T4BL | 17/21 | 26/35 | 25/32 | 11./15 |
CDI-E180G015/P018.5T4BL | 21/24 | 35/38.5 | 32/37 | 15/18.5 |
CDI-E180G018.5/P022T4 | 24/30 | 38.5/46.5 | 37/45 | 18.5/22 |
CDI-E180G022/P030T4 | 30/40 | 46.5/62 | 45/60 | 22/30 |
CDI-E180G030/P037T4 | 40/50 | 62/76 | 60/75 | 30/37 |
CDI-E180G037/P045T4 | 50/60 | 76/92 | 75/90 | 37/45 |
CDI-E180G045/P055T4 | 60/72 | 92/113 | 90/110 | 45/55 |
CDI-E180G055/P075T4 | 72/100 | 113/157 | 110/152 | 55/75 |
CDI-E180G075/P093T4 | 100/116 | 157/180 | 152/176 | 75/93 |
CDI-E180G093/P110T4 | 116/138 | 180/214 | 176/210 | 93/110 |
CDI-E180G110/P132T4 | 138/167 | 214/256 | 210/253 | 110/132 |
CDI-E180G132/P160T4 | 167/200 | 256/305 | 253/300 | 132/160 |
CDI-E180G160/P185T4 | 200/224 | 305/344 | 300/340 | 160/185 |
CDI-E180G185/P200T4 | 224/250 | 344/383 | 340/380 | 185/200 |
CDI-E180G200/P220T4L | 250/276 | 383/425 | 380/420 | 200/220 |
CDI-E180G220T4L | 276 | 425 | 420 | 220 |
CDI-E180P250T4L | 316 | 484 | 480 | 250 |
CDI-E180G250/P280T4L | 316/355 | 484/543 | 480/540 | 250/280 |
CDI-E180G280/P315T4L | 355/395 | 543/605 | 540/600 | 280/315 |
CDI-E180G315/P355T4L | 395/467 | 605/714 | 600/680 | 315/355 |
CDI-E180G355P375T4L | 447/467 | 683/714 | 680/710 | 355/375 |
CDI-E180G375L | 467 | 714 | 710 | 375 |
CDI-E180P400L | 494 | 753 | 750 | 400 |
CDI-E180G400L | 494 | 753 | 750 | 400 |
CDI-E180P500L | 612 | 934 | 930 | 500 |
CDI-E180G500L | 612 | 934 | 930 | 500 |
CDI-E180G630L | 790 | 1206 | 1200 | 630 |
Item | Specification | |
Control | Control mode | V/F control Open-loop vector control (SVC) |
Frequency Resolution | Digital: 0.02% Analog: 0.1% | |
V/F curve | Linear, square root, random V/F | |
Overload capability | 150% rated current 60s; 180% rated current 3s | |
Start torque | G type: 0.5Hz/150% (SVC); | |
Speed Regulation Range | 1:100 (SVC) | |
Stable Speed Accuracy | ±0.5% (SVC) | |
Torque compensation | Manual torque compensation (0.1%-30.0%), automatic torque compensation | |
Configuration | Control power supply +24V | Max. output current 300mA |
Input terminal | The 4-way Digital Input Terminal (DI1-DI4) can be additionally expanded by 2-way (DI5-DI6) through connecting with the IO expansion card, DI6 can be connected with the high speed impulse input 1-way analog input terminal (VF1) which can be additionally expanded by 1-way (VF2) through connecting with the IO expansion card, and it can be also used as digital input terminal via setting. Operating instruction: VF1 can serve as the voltage (0V-10V) or current (0/4mA~20mA) input, however, VF2 can only serve as voltage (0V~10V) input. | |
Output terminal | The 1-way Analog Output Terminal FM1 can be additionally expanded by 1-way (FM2) through connecting with the IO expansion card, both the voltage (0V-10V) and current (0mA~20mA) can be output, the 1-way relay outputs T1, below 30V/1A for DC and below 250V/3A for AC. | |
Operation | Mode of operation | Keyboard, terminal, RS485 communication |
Frequency source | 14 main frequency sources, 14 auxiliary frequency sources. They can be combined and switched via multiple modes. The input mode of each frequency source can adopt multiple ways: keyboard potentiometer, external analog, digital reference, impulse reference, Multiplex Directive, simple PLC, communication, arithmetic results, etc. | |
Torque source | 14 kinds of Torque Sources, including digital reference, external analog, impulse reference, Multiplex Directive, communication, arithmetic results, etc. | |
Acceleration and Deceleration Time | 4-group straight line (terminal switch can be selected via acceleration and deceleration time), S curve 1 and S curve 2. | |
Emergency stop | Interrupt frequency inverter output instantly | |
Multiplex Speed | 16-phase speed is allowable to set at most and use various combination of multiplex directive terminal to switch | |
Simple PLC function | Continuously run 16-phase speed and independently set acceleration and deceleration time and running time | |
Jogging Control | Independently set Jogging frequency and jogging acceleration and deceleration time, additionally, set the unit under running state and confirm whether the jogging is preferential | |
Rotating Speed Tracking | Frequency inverter starts operation by tracking the load speed | |
Fixed-length and fixed-distance control | Realize fixed-length and fixed-distance control function through Impulse Input |