Payment Type: | L/C, T/T, Western Union, Paypal |
---|
Model No.: E180
Series No. | Model | Rated Capacity (kVA) | Rated Input Current (A) | Rated Output Current (A) | Adaptive Motor (kW) | Brake Unit | DC Reactor | LCD Keyboard |
E100/E102 Series | S2 (Single-phase220V, 50/60Hz) | |||||||
CDI-E100G0R4S2B | 0.8 | 5.0 | 2.0 | 0.4 | Standard Built-in | N/A | N/A | |
CDI-E100G0R75S2B | 1.5 | 9 | 4.0 | 0.75 | ||||
CDI-E100G1R5S2B | 2.7 | 15.7 | 7.0 | 1.5 | ||||
CDI-E100G2R2S2B | 3.8 | 27 | 10.0 | 2.2 | ||||
T2 (Three-phase 220V, 50/60Hz) | ||||||||
CDI-E100G0R4T2B | 0.8 | 2.3 | 2.0 | 0.4 | Standard Built-in | N/A | N/A | |
CDI-E100G0R75T2B | 1.5 | 6 | 4.0 | 0.75 | ||||
CDI-E100G1R5T2B | 2.7 | 8.8 | 7.0 | 1.5 | ||||
CDI-E100G2R2T2B | 3.8 | 12.5 | 10.0 | 2.2 | ||||
T4 (Three-phase 380V, 50/60Hz) | ||||||||
CDI-E100G0R75T4B | 1.5 | 3.4 | 2.3 | 0.75 | Standard Built-in | N/A | N/A | |
CDI-E100G1R5T4B | 3.0 | 5.0 | 3.7 | 1.5 | ||||
CDI-E100G2R2T4B | 4.0 | 5.8 | 5.1 | 2.2 | ||||
CDI-E100G3R7T4B | 5.9 | 10.5 | 8.8 | 3.7 | ||||
E180 Series | T4 (Three-phase 380V, 50/60Hz) | |||||||
CDI-E180G0R75T4B | 1.5 | 3.4 | 2.3 | 0.75 | Standard Built-in | N/A | Optional | |
CDI-E180G1R5T4B | 3 | 5.0 | 3.7 | 1.5 | ||||
CDI-E180G2R2T4B | 4 | 5.8 | 5.0 | 2.2 | ||||
CDI-E180G3R7/P5R5T4B | 5.9/8.5 | 10.5/15.5 | 8.8/13 | 3.7/5.5 | ||||
CDI-E180G5R5MT4B | 8.5 | 15.5 | 13 | 5.5 | ||||
CDI-E180G5R5/P7R5T4B | 8.5/11 | 15.5/20.5 | 13/17 | 5.5/7.5 | ||||
CDI-E180G7R5/P011T4B | 11/17 | 20.5/26 | 17/25 | 7.5/11 | ||||
CDI-E180G011MT4B | 17 | 26 | 25 | 11 | ||||
CDI-E180G011/P015T4BL | 17/21 | 26/35 | 25/32 | 11/15 | Standard Built-in | |||
CDI-E180G015/P018.5T4BL | 21/24 | 35/38.5 | 32/37 | 15/18.5 | ||||
CDI-E180G018.5/P022T4 | 24/30 | 38.5/46.5 | 37/45 | 18.5/22 | Optional Built-in | Optional Built-in | ||
CDI-E180G022/P030T4 | 30/40 | 46.5/62 | 45/60 | 22/30 | ||||
CDI-E180G030/P037T4 | 40/50 | 62/76 | 60/75 | 30/37 | ||||
CDI-E180G037/P045T4 | 50/60 | 76/92 | 75/90 | 37/45 | Optional Built-out | |||
CDI-E180G045/P055T4 | 60/72 | 92/113 | 90/110 | 45/55 | ||||
CDI-E180G055/P075T4 | 72/100 | 113/157 | 110/152 | 55/75 | ||||
CDI-E180G075/P093T4 | 100/116 | 157/180 | 152/176 | 75/93 | Optional Built-out | |||
CDI-E180G093/P110T4 | 116/138 | 180/214 | 167/210 | 93/110 | ||||
CDI-E180G110/P132T4 | 138/167 | 214/256 | 210/253 | 110/132 | ||||
CDI-E180G132/P160T4 | 167/200 | 256/305 | 253/300 | 132/160 | ||||
CDI-E180G160/P185T4 | 200/224 | 305/344 | 300/340 | 160/185 | ||||
CDI-E180G185/P200T4 | 224/250 | 344/383 | 340/380 | 185/200 | ||||
CDI-E180G200/P220T4 | 250/276 | 383/425 | 380/420 | 200/220 | Standard Built-in | |||
CDI-E180G220/P250T4 | 276/316 | 425/484 | 420/480 | 220/250 | ||||
CDI-E180G250/P280T4 | 316/355 | 484/543 | 480/540 | 250/280 | ||||
CDI-E180G280/P315T4 | 355/395 | 543/605 | 540/600 | 280/315 | ||||
CDI-E180G315/P355T4 | 395/447 | 605/683 | 600/680 | 315/355 | ||||
CDI-E180G355/P375T4 | 447/467 | 683/714 | 680/710 | 355/375 | ||||
CDI-E180G375/P400T4 | 467/494 | 714/753 | 710/750 | 375/400 | ||||
CDI-E180G400/P500T4 | 494/612 | 753/934 | 750/930 | 400/500 | ||||
CDI-E180G500/P630T4 | 612/790 | 934/1206 | 930/1200 | 500/630 | ||||
CDI-E180G630T4 | 790 | 1206 | 1200 | 630 |
Item | Specifications | ||
Control | Control method | V/F control Vector control SVC Vector control VC Invalid for E100/E102 series | |
Frequency accuracy | Digital value 0.02% Analogue value 0.1% | ||
V/F curve | Linear Squareroot Any V/F | ||
Overload capacity | G type machine: 150% rated current 60s; 180% rated current 3s P type machine: 120% rated current 60s; 150% rated current 3s | ||
Starting torque | G type machine: 0.5Hz/150% SVC; 0Hz/180% VC | ||
Speed regulation scope | 1:100 SVC | 1:1000 SVC | |
Speed stabilizing scope | 0.5% SVC | 0.02% | |
Torque control precision | 5% VC | ||
Torque compensation | Manual torque compensation 0.10% 30.0% Automatic torque compensation | ||
Operation mode | Keyboard, terminal, RS 485 communication | ||
Functions of basic type | Frequency source | 14 types of main frequency sources, 14 types of auxiliary frequency sources. Combined switching-over in multiple ways are available. Diversified input method of frequency source, keyboard potentiometer, external analog quantity, digital set point, pulse frequency, multi-speed, simple PLC, communication, operation results. | |
Torque source | 14 types of torque source, including digital set point, external analog quantity, pulse set point, multi-stage instructions, communication, operation results. | ||
Time of ACC/DEC | 4 groups of straight lines, switchable by means of time of ACC/DEC, S curve 1, S curve 2 | ||
Emergency shut down | Stop the output of the frequency inverter suddenly | ||
Multi-speed | It may set 16 speeds maximally, which may be switched by means of multi instruction terminals. | ||
Simple PLC function | It may set 16 speeds, and the deceleration time, operation time and frequency source may be set independently. | ||
Jogging control | The jogging frequency and jogging time of ACC/DEC may be set independently, and it may also set the preference to jogging under operation status. | ||
Speed tracking | The load speed tracked by the frequency inverter is started. | ||
Fixed-length, fixed-distance control | It may realize the fixed-length and fixed-distance control by the pulse input. | ||
Counting control | It may realize the counting function by the pulse input. | ||
Swinging control | It may be applied for the winding equipment of textiles. | ||
Built-in PID | It may realize SVC. | ||
AVR function | It may ensure the output of constancy in voltage fluctuation of network. | ||
DC brake | It may stop the machine steadily and quickly. | ||
Slip compensation | It is to compensate the slip deviation caused by increased load. | ||
Hopping frequency | It is to prevent the resonance with load. | ||
Dropping function | It is to balance the several motors with the same load. | ||
Timing control | The frequency inverter may stop working after the given time. |
Item | Specification | |
Functions of enhanced type | Built-in virtual delay timer | It may conduct simple logic programming for multi-functional output terminals and digital input terminals; therefore, it may be considered as equivalent to the digital input terminal and may realize output via multi-functional output terminal. |
Built-in timer | It has 2 built-in timers to collect input timing signals and then output the signals. Those timers may be used together or independently. | |
Built-in operation module | It has 1 quad operation module and may conduct simple addition, subtraction, multiplication, division, judgment of size and integral operations. | |
Communication | E100 | The control panel has RS 485 communication interface and it supports MODBUS protocol. |
E102/E180 | The control panel has no RS communication interface and shall be installed with an external communication expansion card. It supports standard MODBUS protocol and may be installed with MODBUS communication expansion card. | |
Encoder | E100 | It may connect to the encoder via DI5 and DI6 terminals on the control panel. Such connection may realize SVC easily via PID control and may be applied to those requiring lower control precision. |
E180 | Since the control panel has no encoder interface, it shall be installed with an expansion card. It supports ABZ incremental encoder, UVW incremental encoder and rotary transformers. Such connection may realize high performance VC and may be applied for those requiring higher control precision. | |
Type of motor | E100/E102 | It can only drive the asynchronous motor |
E180 | It may drive the asynchronous motor and the synchronous motor. | |
Display | Operation information | Given frequency, output frequency, output voltage, bus voltage, input signal, feedback value, modular temperature, output frequency, synchronous speed of motor. It may show 32 information by use of >> key. |
Error information | It may save the 3 failure information with frequency, current, bus voltage, output/input terminal status when failed under failure protection status. | |
Protection | Frequency inverter protection | It may protect the equipment against over current, over voltage, modular failure, under voltage, over heat, over load, external failure, EEPROM failure protection, grounding protecting and default phase. |
Alarm of frequency inverter | It may protect the equipment and send over-load alarm | |
Instant power down | It may keep running in the case of lower than 15 ms. It may be restarted automatically in the case of larger than 15 ms. | |
Environment | Ambient temperature | -10~40 |
Storage temperature | -10~40 | |
Ambient humidity | 90% RH maximally, non-condensing | |
Height/vibration | Lower than 1000m, 0.6g | |
Place of application | No etchant gas, inflammable gas, oil mist or dust. | |
Cooling method | Forced cooling |